What Is what FLEXQ module, Continued Parts and The components are as follows: functions (continued) Part Function FLEXQ sampler tray FLEXQ sampler tray moves to the position for measurement by means of a step motor (not shown).Environmental Indoor use statement added according to CSA regulations: requirements Location.Clot-detection process During calibration the measuring chamber is rinsed and the pH of the Rinse solution is measured.
Radiometer Abl80 Flex Co Ox Manual Next TimeData in this document will be added to the manual next time it is updated. Troubleshooting 12. Sampling 13. Specifications 14. Ordering information 15. Radiometer Abl80 Flex Co Ox Software Included InRadiometer Abl80 Flex Co Ox Free From DefectsRadiometer warrants that the data media on which the software included in the system is furnished is free from defects in material and workmanship under normal use for three (3) months from the date of delivery as evidenced by a copy of invoice or receipt. Those installed software products of MS origin, as well as associated media, printed materials and online or electronic documentation (SOFTWARE) are protected by international intellectual property laws and treaties. Replacements.7-1 Overview.7-1 General information.7-2 Replacing membranes or electrodes.7-6 Replacing pump tubes.7-9 Replacing inlet gasket unit and inlet probe. Replacing waste container, fan filter, printer paper.7-14 Replacing solutions and gases. ![]() Radiometer settings.15-1 Overview.15-1 Radiometer default settings.15-2 Contents of setup settings.15-15 Calibration verification. Throughout this manual, ABL800 FLEX analyzer is used for all ABL8xx FLEX analyzers, i.e.: ABL837835830827825820817815810805 and ABL810 BG only. Common name: Blood gas, oximetry, electrolyte and metabolite measuring system. Some on animal blood components in animal blood differ from those in human blood, and variations in the composition of blood from different animal species may also exist. ![]() ABL800 FLEX analyzers do not compensate for this. Thus Radiometer recommends the exclusive use of heparin as anticoagulant. Solutions containing organic preservatives may damage the ion- selective membranes of the c K and c Glu electrodes when introduced into the analyzer. Galactose, glucosamine, maltose, Erroneously high c Glu measurements. Introduction WarningCaution and Notices Throughout the manual, the various procedures may contain operational cautions Definitions and warnings, which are important and should be read carefully before performing the related procedures. Symbol Explanation Biohazard Expiry date See instructions for use For In Vitro Diagnostic Use Lot number Sensitive to light. This chapter describes the basic parts of the ABL800 FLEX analyzer and its software. What Is what Analyzer - front, Continued Parts and The components of the analyzer front (without covers) is shown below. If source is 240 V, use Radiometer cord 615-405 with tandem blade attachment plug. What Is what Measuring section Parts and The modules and components of the measuring section are shown below. What Is what Inlet module Parts and The inlet module accepts samples from a syringetest tube or a capillary (the functions syringe and capillary inlet flaps are removed on the picture). Syringe and capillary inlet flaps are interlocked so that only one may be opened at a time.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |